Single Phase

Earth Leakage Relays

Features of KEW-AVM-IP:

  • Display: 1 Row of 3/4 Digit LED Display (Model-wise)
  • Measured Parameters: Earth Leakage Current (10mA – 30A, Settable), Imbalance Current
  • Phase Sequence Protection: Yes – Ensures correct phase sequence detection (applicable for 3Ø system)
  • Communication & Features: RS-485 MODBUS RTU (Optional), Two Relay Outputs (Optional), CICT Slot for Plug-in CTs, Delay Time Programmable 

Specification of AC Monitor Protection Relay

  • Trip Current
    Range:
    10mA – 30A (Settable)
    Trip Delay- 100ms – 5000ms (Settable)
  • Relay Contact :
    8AMPS/16AMP, 250V AC POTENTIAL FREE
  • Auxiliary Supply: 45–270V AC/DC or 90–440V AC/DC (Dual supply)
  • Relay Output:
    1 Relay Output (2A @ 250V AC), for tripping or alarm signaling
  • Output Relay: 1 C/O, 8A / 250V AC, Potential Free
  • CT Secondary: 5A (Compatible with CBCT)
  • Display: S-ELR+– (3 Digit 7-Segment RED LED Display)
    D-ELR+ — (4 Digit RED LED Display)
  • Indications: Error Code Display, Fault LED Indicators
  • Mounting Type: Panel Mount
  • Faceplate: Polycarbonate Transparent
  • Case/Housing Material: FR-ABS Black
  • Connectors/Terminal: Nylon 666, 33%GF
  • Mounting Clamps: Sturdy, Moulded Glass filled nylon with screws
  • Panel Dimensions: S-ELR+:-(96X96) D-ELR+:-(95X35)
  • Working Temperature: –10°C to +55°C
  • Storage Temperature: -10°C to 60°C
  • IEC62052-11

Panel Cutout Dimensions

Terminal Connection

Applications and Industries where it is used

Distribution Panels for Commercial Buildings

  • Where: In distribution panels of commercial buildings, typically downstream of the main incomer, protecting circuits feeding floors, offices, HVAC systems, and lighting.

  • Why: To detect leakage currents caused by insulation faults or faulty equipment and trip the circuit before it poses a shock hazard or causes fire, ensuring personnel safety, equipment protection, and compliance with electrical safety standards.

UPS & IT Server Power Panels

  • Where: In UPS-backed power panels and IT server room distribution boards supplying critical loads such as server racks, network switches, and storage systems.

  • Why: To detect and isolate earth leakage currents from faulty UPS circuitry, power distribution units, or server power supplies before they lead to electric shock, fire hazards, or downtime — ensuring equipment protection, personnel safety, and uninterrupted operation of mission-critical IT infrastructure.

Industrial MCC Panels with Dual Feeders

  • Where: Installed in manufacturing plants, process industries, or heavy-load facilities where motors can be powered from two separate incoming sources (e.g., utility supply and generator).

  • Why: To monitor and trip circuits when earth leakage currents occur on either feeder, protecting motors, drives, and downstream loads from insulation breakdown or ground faults, while ensuring safe changeover between feeders without risking shock hazards, fire, or equipment damage.

Solar Inverter & Battery Bank Installations

  • Where: In solar inverter output panels and battery bank distribution boards for renewable energy systems in commercial, industrial, or residential setups.

  • Why: To detect leakage currents from faulty inverter circuits, damaged DC/AC cabling, or degraded battery insulation and disconnect the affected circuit before it causes electric shock, fire hazards, or equipment failure — ensuring personnel safety, system reliability, and compliance with electrical safety standards for renewable installations.

Ordering Information

Model Accuracy Class Display & Protection Aux Supply
KEW-ELR (S-ELR+) ±0.5% IMBALANCE CURRENT 45–270V AC/DC, 90–440V AC/DC
KEW-ELR(D-ELR+) ±0.5% IMBALANCE CURRENT 45–270V AC/DC, 90–440V AC/DC