Single Phase

KEW-AC Three Phase Multifunction Meter

Features of KEW-AVM-IP:

  • Display: 3-row, 4-digit bright LED display
  • Measured Parameters:
    • V, I, kW, kVA, kVAR, PF (Cos Φ), Hz, kWh, kVAh, kVARh,Rh,Lrh
  • Flexible Integration: Features RS-485 & MODBUS RTU communication (optional),
    programmable CT/PT ratios, and wide auxiliary supply support.
  • Accuracy: ±0.5% for Voltage, Current, Power
  • Size: 96×96

Specification of AC Three Phase Multifunction Meter

  • Auxiliary Supply:  45-270V AC/DC,  18–60 V AC/DC (Optional range)
  • CT / PT Ratio Programmability: User programmable via keypad
  • Accuracy Class: 1 & 0.5
  • VA Burden:
    Auxiliary: < 1.5VA
    Voltage Input: <0.2 VA/Phase
    Current Input: <0.2VA/Phase
  • Input CT/PT
    Programable
    Range:
    Direct: 20–750 V
    PT Operated: Up to 500 kV (Prim), 60–600 V (Sec)
    CT Operated: Up to 50kA (Prim), 0.5A to 5A (Sec)
  • Impulse Withstand: 3.5KV for 1.2/50 micro second
  • Display: 4 Digit 7 Seg RED LED Display
  • Digit Height: 0.56”/14.2mm
  • Display Stability: With in +-1 Digit
  • Decimal Point: Auto Scrolling and Manual
  • Refresh Rate: Per 8.0ms
  • Mounting Type: Panel Mount
  • Faceplate: Polycarbonate Transparent
  • Case/Housing Material: FR-ABS Black
  • Connectors/Terminal: Nylon 666, 33%GF
  • Mounting Clamps: Sturdy, Moulded Glass filled nylon with screws
  • Working Temperature: 0°C to 60°C
  • Storage Temperature: 0°C to 55°C
  • IEC62052-11

Panel Cutout Dimensions

Terminal Connection

Applications and Industries where it is used

Electrical Panel

  • Where: Used in main LT panels and distribution panels to monitor multiple electrical parameters like voltage, current, power, power factor, frequency, and energy.
  • Why: To provide comprehensive real-time monitoring for efficient load management, fault detection, and energy optimization.

Building Management Systems (BMS)

  • Where: Used in BMS panels to monitor electrical parameters of key building systems like HVAC, elevators, and lighting across all three phases.

  • Why: To enable centralized energy monitoring, detect anomalies, and ensure efficient operation of building infrastructure.

Generator / DG Set Panels

  • Where: Used on the output side of Generator / DG Set panels to monitor voltage, current, power, power factor, and frequency across all phases.

  • Why: To ensure balanced load distribution, prevent generator overload, and maintain stable power quality during operation.

Commercial Sub Metering / Retail Malls

  • Where: Used in tenant and main distribution panels of commercial sub-metering systems in retail malls to monitor comprehensive electrical parameters for each zone or tenant.

  • Why: To enable detailed energy monitoring, ensure balanced load usage, support accurate billing, and enhance overall power management.

Ordering Information

Model Parameters Displayed Accuracy Aux Supply Dimensions (MM)
ACMM-BG-1V (96×96) • Voltage (Line to Line)
• -Voltage (Line to Neutral)
• Current
• -Frequency (Class 0.2)
• Load Hours
• Run Hours
0.5
1.0
• 150-300V AC (TX Supply)
• 45-270V AC/DC
• 19-60V AC/DC
96×96
Model Parameters Displayed Accuracy Aux Supply Dimensions (MM)
ACMM-BG-3V (96×96)
• Voltage (Line to Line) • Voltage (Line to Neutral) • Current • Frequency (Class 0.2) • Power Factor (Class 0.5) • RPM • Run Hour • Load Hour
0.5 / 1.0
• 45-270V AC/DC • 19-60V AC/DC
96×96