Single Phase

Three Phase

KEW-AC Power Factor Meter

Features of KEW-AVM-IP:

  • Display: 7-Segment 4-Digit LED Display
  • Measured Parameters:
    • Power Factor (Cos Φ), Frequency (Hz), Lag/Lead Indication
  • Flexible Integration: RS-485 MODBUS communication (optional), User-programmable
    setup, Alarm relay (optional), Compact panel mount design
    (96×96 mm)
  • Accuracy: ±0.5% for Voltage, Current
  • Size: 96×96

Specification of AC Single Phase Voltmeter

  • Auxiliary Supply: 150-300V AC, 45-270V AC/DC, 19-60V AC/DC
  • Measuring
    Method :

    Cosine of Phase Shift Between Voltage & Current
  • VA Burden:
    Auxiliary: < 1.5VA
    Voltage Input: <1.0VA
    Current: ≤1.0 VA
  • Polarity Indication: Lagging (L) / Leading (C)
  • Input Specifications: Input Voltage: 0 – 750V AC (Direct)
    Input Current: 0.020 – 10A AC (Direct)
  • Display: 4 Digit 7 Seg RED LED Display
  • Digit Height: 0.56”/14.2mm
  • Display Stability: With in +-1 Digit
  • Decimal Point: Auto Scrolling and Manual
  • Refresh Rate: Per 8.0ms
  • Mounting Type: Panel Mount
  • Faceplate: Polycarbonate Transparent
  • Case/Housing Material: FR-ABS Black
  • Connectors/Terminal: Nylon 666, 33%GF
  • Mounting Clamps: Sturdy, Moulded Glass filled nylon with screws
  • Working Temperature: 0°C to 60°C, RH<70%
  • Storage Temperature: -10°C to 70°C, RH<70%
  • IEC62052-11

Panel Cutout Dimensions

Terminal Connection

Applications and Industries where it is used

Electrical Panel

  • Where: Power Factor (PF) meters are used in capacitor panels, LT panels, and distribution panels to monitor reactive power
  • Why: To monitor and correct power factor, enhance energy efficiency, and reduce electricity costs and penalties.

Building Management Systems(BMS)

  • Where: Power Factor (PF) meters are used in BMS panels to monitor the power factor of building electrical loads.

  • Why: To improve energy efficiency, avoid utility penalties, and ensure optimal load management.

Generator / DG Set Panels

  • Where: PF meters are used on the output side of Generator / DG Set panels.

  • Why: To ensure efficient generator performance, prevent overloading, and maintain voltage stability.

Commercial Sub Metering / Retail Malls

  • Where: PF meters are used in tenant distribution panels and main sub-metering panels of retail malls

  • Why: To optimize energy usage, avoid power factor penalties from utilities, and ensure balanced load management across tenants or zones.

Ordering Information

Model Measuring Range Accuracy Aux Supply Dimensions (MM)
ACPM-BG-1V (96×96) Voltage Input: 20–750V AC (Direct)
Current Input:
• 0.080–10A AC (Direct)
• 0.020–1A AC (Direct)
• 0.1A–30A AC (Direct)
0.5 • 150–300V AC (TX Supply)
• 45–270V AC/DC
• 19–60V AC/DC
96×96
Model Measuring Range Accuracy Aux Supply Dimensions (MM)
ACPM-BG-3V (96×96)
Voltage Input: 200–600V (Line to Neutral),30– 1000V (Line to Line) Current Input: • 0.020–10A AC • 0.1A–30A AC (Per Phase)
0.5
• 150–300V AC (TX Supply) • 45–270V AC/DC • 19–60V AC/DC
96×96