Single Phase

Three Phase

KEW-AC Ammeter

Features of KEW-AVM-IP:

  • Display: 7-Segment 4-Digit LED Display
  • Measured Parameters: Current (Phase-wise & Average), True RMS
  • Flexible Integration: RS-485 & MODBUS RTU communication (optional), programmable
    CT ratios, wide auxiliary supply range
  • Accuracy Class: ±0.1% – ±0.5%
  • Size: 96×96, 72×72, 48×96 mm (customizable)

Specification of AC Single Phase Ammeter

  • Auxiliary Supply: 45–270V AC/DC
    18–60V AC/DC
  • Input CT
    Programmable
    Range :

    1A to 50kA (Primary), 0.5A to 5A (Secondary)
  • Accuracy: ±0.1% -±0.5%
  • VA Burden:
    Auxiliary: < 1.5VA
    Voltage Input: <0.2VA/Phase
  • CT Ratio
    Programmability:
    User programmable
  • Impulse Withstand Voltage: 3.5KV for 1.2/50 micro second
  • Display: 4 Digit 7 Seg RED LED Display
  • Digit Height: 0.56”/14.2mm
  • Display Stability: With in +-1 Digit
  • Mounting Type: Panel Mount
  • Faceplate: Polycarbonate Transparent
  • Case/Housing Material: FR-ABS Black
  • Connectors/Terminal: Nylon 666, 33%GF
  • Mounting Clamps: Sturdy, Moulded Glass filled nylon with screws
  • Working Temperature: 0°C to 60°C
  • Storage Temperature: -10°C to 70°C
  • IEC62052-11

Panel Cutout Dimensions

Terminal Connection

Applications and Industries where it is used

Electrical Panel Manufacturing

  • Where: Mounted on control panels, distribution boards, and starter panels.
  • Why: To measure and monitor the real-time current flowing through circuits.

Building Management Systems (BMS)

  • Where: Used in main panels, subpanels, HVAC, lighting, and tenant metering units within a BMS.

  • Why: help monitor current flow, detect faults, and optimize energy usage across building systems.

Generator / DG Set Panels

  • Where: Installed on the generator control panel to display the phase-wise output current.

  • Why: To monitor output current and ensure the generator operates within safe load limits.

Commercial Sub-Metering / Retail Malls

  • Where: Installed inside individual distribution boards or sub-panels allocated to each shop or tenant.

  • Why: to measure individual tenant or shop-wise energy consumption for accurate billing and energy management.

Ordering Information

Model Measuring Range Accuracy Aux Supply Dimensions (MM)
ACAM-BG-1A 10–35uA/0.2–20mA / 10–750mA
0.020–10A AC (Direct)
0.1A-30A (Direct)
CT program up-to 50kA
0.5
1.0
0.5
150–300V AC
45–270V AC/DC
19–60V AC/DC
96×96
ACAM-SG-1A 10–35uA/0.2–20mA / 10–750mA
0.020–10A AC (Direct)
0.1A-30A (Direct)
CT program up-to 50kA
0.5
1.0
0.5
15–300V AC/DC
45–270V AC/DC
19–60V AC/DC
72×72
ACAM-RECT-1A 10–35uA/0.2–20mA / 10–750mA
0.020–10A AC (Direct)
0.1A-30A (Direct)
CT program up-to 50kA
0.5
1.0
0.5
150–300V AC/DC
45–270V AC/DC
19–60V AC/DC
48×96
Model Measuring Range Accuracy Aux Supply Dimensions (MM)
ACAM-BG-3A (96×96)
0.020A–10A AC or 0.1–30A AC (Direct) (Per Phase)
0.5 /1.0
150–300V AC 45–270V AC/DC 19–60V AC/DC
96×96
ACAM-SG-3A (72×72)
20–750V AC
0.5 / 1.0
15–300V AC / 45–270V AC/DC / 19–60V AC/DC
72×72